Probe F |
Peobe N |
| Measuring principle |
Magnetic induction |
Eddy currents |
| Measuring range |
0 to 1300µm (0 to 51.2 mils) |
0 to 1300µm (0 to 51.2 mils) |
| Accuracy |
±(3% +2 µm)±(3% +0.078 mils) |
±(3% +2 µm)±(3% +0.078 mils) |
| Resolution |
0 µm~999 µm(1 µm)1000 µm~1300 µm (0.01mm)0 mils~39.39 mils(0.01mils)39.4 mils ~51.2 mils(0.1mils) |
0 µm~999 µm(1 µm)1000 µm~1300 µm (0.01mm)0 mils~39.39 mils(0.01mils)39.4 mils ~51.2 mils(0.1mils) |
| Calibration |
One point to for point calibration, zero point calibration , basic |
| Data group |
One direct group (readings not be stored to memory)Four general group (readings will be stored automatically)NOTE: each group have individual statistics, alarm limit settings and calibration |
| Statistics |
No. of readings, Mean minimum, maximum and standard deviation. |
| Units |
Um, mm, mils |
| Alarm |
User can set the high/ low alarm limit Alarm icon displayed on LCD when over the limit |
| Minimum curvature radius convex |
1.5mm |
| Minimum curvature radius concave |
25mm |
| Minimum measuring area |
Diameter 6mm |
| Minimum thickness ofsubstrate |
0.5mm (0.02”) |
0.3mm(0.012”) |
| Maximum measuring rate |
Two readings per second |
| Computer interface |
Download data via USB |
| Power supply |
Two 1.5v AAA battery |
| Operation environment |
Temperature ; 0 to 40◦C (32 to 104◦F); humidity : 20% to 90%rh |
| Storage environment |
Temperature ; 20 to 70◦C (-4 to 158◦F); |
| Standard compliance |
ROHS WEEE |
| Size |
110mm x 53mm x 24mm(4.33” x 2.09” x 0.94”) |
| Case material |
ABS; 92g(3.24oz) |