FEATURES
- 128*128 dot matrix LCD display, standard menu operations;
- Two measure mode : single and continuous;
- Two group mode: direct (dir) and general (gen), readings will be lost when power off in direct mode, and not be lost in general mode. 80 readings can be stored for each group;
- Zero point calibration and multi-point calibration (up to 4 points) for each group;
- Users can recall, delete specified readings, or delete group readings;
- Statistics display: Mean minimum, maximum and standard deviation.
- Three probe mode: auto , magnetic and eddy current.
- User can set high or low limit alarm for each group.
- Power off automatically.
- USB interface to data transmission.
- Low battery and error indication.
Specifications
Probe F | Peobe N | ||
Measuring principle | Magnetic induction | Eddy currents | |
Measuring range | 0 to 1300µm (0 to 51.2 mils) | 0 to 1300µm (0 to 51.2 mils) | |
Accuracy | ±(3% +2 µm)±(3% +0.078 mils) | ±(3% +2 µm)±(3% +0.078 mils) | |
Resolution | 0 µm~999 µm(1 µm)1000 µm~1300 µm (0.01mm)0 mils~39.39 mils(0.01mils)39.4 mils ~51.2 mils(0.1mils) | 0 µm~999 µm(1 µm)1000 µm~1300 µm (0.01mm)0 mils~39.39 mils(0.01mils)39.4 mils ~51.2 mils(0.1mils) | |
Calibration | One point to for point calibration, zero point calibration , basic | ||
Data group | One direct group (readings not be stored to memory)Four general group (readings will be stored automatically)NOTE: each group have individual statistics, alarm limit settings and calibration | ||
Statistics | No. of readings, Mean minimum, maximum and standard deviation. | ||
Units | Um, mm, mils | ||
Alarm | User can set the high/ low alarm limit Alarm icon displayed on LCD when over the limit | ||
Minimum curvature radius convex | 1.5mm | ||
Minimum curvature radius concave | 25mm | ||
Minimum measuring area | Diameter 6mm | ||
Minimum thickness ofsubstrate | 0.5mm (0.02”) | 0.3mm(0.012”) | |
Maximum measuring rate | Two readings per second | ||
Computer interface | Download data via USB | ||
Power supply | Two 1.5v AAA battery | ||
Operation environment | Temperature ; 0 to 40◦C (32 to 104◦F); humidity : 20% to 90%rh | ||
Storage environment | Temperature ; 20 to 70◦C (-4 to 158◦F); | ||
Standard compliance | ROHS WEEE | ||
Size | 110mm x 53mm x 24mm(4.33” x 2.09” x 0.94”) | ||
Case material | ABS; 92g(3.24oz) |