Features:-
Brief Introduction:
TC100 is used to detect the thickness of concrete covering layer and rebar diameter. Besides, it can detect the location of magnetic substance and electric conductor in non-magnetic and non-conductive medium, e.g. cable inside wall body and water & heating pipe etc. This instrument is a kind of intelligent nondestructive test equipment possessing the functions of automatic detection, data memory and output.
Measuring the thickness of concrete over steel reinforcement and metal pipes
Measuring the rebar location and diameter
Large graphic display with backlight
Signal strength bar display and sound alarm for accuracy reading
Depth of covering layer reach up to 180mm
Real time graphic output both to screen and printer
Data processing software compatible with windows 95/98/2000/Me/WT/XP
Auto calibration, correct the system error
Three scan mode: grid pattern ,profile scan and large area scan
Technical Specification:-
Covering layer thickness measuring range |
Range :6mm~90mm | |
Range : 7mm~180mm | ||
Rebar diameter measuring range | Ø6mm~ Ø50mm | |
Tolerance of covering layer thickness | Range | Range |
±1mm | 6mm~59mm | 7mm~79mm |
±2mm | 60mm~69mm | 80mm~119mm |
±4mm | 70mm~90mm | 120mm~180mm |
Operating temperature | -10 ~ 40 | |
Relative humidity | <90% |